Hanna Instruments New Zealand
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality 360 Value

EC/Resistivity Probe for HI6321 - HI7631233

The HI7631233 is a four-ring conductivity/resistivity/TDS/salinity probe to use with the HI6321 benchtop meter.

Recommended for a wide range of industrial process water applications, HI7631233 provides stable measurements over a wide measurement range and does not require frequent calibrations. An integral temperature sensor measures the process temperature and adjusts the measured conductivity to a reference temperature by applying specialized compensation algorithms

Mediray is Hanna Instruments’ authorised distributor in New Zealand. To purchase our products, please see the details below.

The HI7631233 integrated temperature sensor adjusts the measured conductivity to a reference temperature by applying compensation algorithms. The electrolytic conductivity (EC) reading from the HI7631233 sensor can be used to calculate Total Dissolved Solids (TDS), Resistivity, and Salinity (PSU, ppt, or %).

  • TDS is a calculated value based on the conductivity of the solution (TDS = factor × EC25). A TDS factor is a conversion factor used to change an EC measurement to a ppm (or ppt) measurement.
  • Salinity (PSU) relates the ratio of electrical conductivity of a normal seawater sample at 15 °C and 1 atmosphere to a potassium chloride solution (KCl) with a mass of 32.4356 g/Kg water at the same temperature and pressure. Under these conditions, the ratio is equal to 1 and S=35. The practical salinity scale may be applied to values 0 through 42.00 psu at temperatures between 0 to 35 °C.
  • Salinity (ppt) measurements are based on the 0.00 to 80.00 g/L Natural Seawater Scale from 10 to 31 °C. It determines the salinity based upon a conductivity ratio of sample to standard seawater at 15 °C and an approximate salinity value of 35 in seawater.
  • Salinity (%) in this scale 100% salinity is equivalent to roughly 10% solids.

 

Specifications

SKU

HI7631233

Name

EC/Resistivity Probe for HI6321

Range

0 to 1000 mS/cm

Recommended operating temperature

Built-in

Cell constant

1 ± 15 %

Cell type

Four-ring, platinum on glass

Body

Polyetherimide (PEI)

Sensor diameter

Ø 12.0 mm

Connection

DIN

Cable length

1 m (3.3’)

 

Additional information

Weight 0.45 kg
Parameter

Conductivity/TDS

EC Accuracy

±1% of reading (±0.01 µS/cm or 1 digit, whichever is greater)

EC Resolution

0.001 µS/cm; 0.01 µS/cm; 0.1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm

Where to buy

Mediray is Hanna Instruments’ authorised distributor in New Zealand. To purchase our products, please see the details below.

Phone: 0800 633 472

[email protected]

www.mediray.co.nz