Hanna Instruments New Zealand
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality 360 Value

Automatic Potentiometric Titration System - HI930

The HI930 Automatic Potentiometric Titration System is the answer to your basic titration needs. The HI930 delivers accurate results and intuitive user experience, all in a compact package.

Mediray is Hanna Instruments’ authorised distributor in New Zealand. To purchase our products, please see the details below.

The HI930 Automatic Potentiometric Titration System is the answer to your basic titration needs. The HI930 delivers accurate results and intuitive user experience, all in a compact package. Titrate for a variety of measurements at the push of a button including acids, bases, and redox. With no additional programming upgrades to purchase, you can start measuring right away.

Maximize your workspace
This new generation of titrator features a compact footprint for maximum use of your lab space. Use it in any sized space while providing accurate and consistent results.

Simple user experience
Virtual keys present on the display allow for simple and quick navigation between screens and menus without getting lost in a nest of information. If you need additional information about a screen, simply press the dedicated button for help.

Designed for dynamic environments
Don’t worry about small spills in the laboratory with built-in spill handling. An external gutter system protects important connections and interior trays safeguard internal electronics.

Superior design for superior results
The Cycoloy® body is durable, heat-resistant, and resists staining. Menu buttons are part of the display making it fully sealed and easy to clean.

Titrator capabilities

Multiple titration types
Paired with the right electrode, this potentiometric titrator can perform any number of standard titrations including pH and mV tests with fixed endpoints or single equivalence points.

Dynamic titrant dosing
The dynamic dosing feature allows for timely and accurate titration results by relating the titrant volume dosed to the mV response from the titration reaction. This provides for larger doses near the beginning of a titration and smaller, more precise doses near the titration endpoint.

Equivalence endpoint detection
Equivalence endpoint detection is critical in applications where fixed endpoints are not specified in standard methods. This endpoint indicates where the mV response from the titration is greatest with respect to the volume of titrant dosed.

Signal stability timing
The signal stability feature monitors when the mV response of the titration reaction stabilizes before providing the next titrant dose. This ensures reliable measurement values throughout the length of a titration.

Customizable methods
This titrator can store up to 15 user-defined or standard titration and direct measurement methods. Each method may be modified and optimized for performance based on application and user requirements.

Customizable analysis reports
Each analysis report is fully customizable to ensure the best data required for an application is stored and filed. The Multiselect feature makes batch processing simple.

Burettes and dosing system

Clip Lock™ exchangeable burette system
With Hanna’s Clip-Lock™ burette feature, it only takes a few seconds to exchange titrants and reagents preventing cross-contamination and saving time.

Multiple burette sizes
HI930 is supplied with a 10 mL burette but may be equipped with a 5 mL, 25 mL, or 50 mL burette. Each burette is constructed with a ground glass syringe and chemically resistant PTFE plunger.

Precision dosing pump
Our unmatched 40,000-step piston driven pump is capable of dosing extremely small and highly accurate volumes of titrant or reagent.

Chemically resistant tubing
Aspiration and dispensing tubes are constructed of durable, chemically resistant PTFE and feature a light-blocking polyurethane outer sleeve to protect light sensitive reagents.

 

Interface and display

Interactive color display
A large, high contrast LCD display clearly shows the chosen titration method along with results, units, titration volume, temperature, and mV or pH values. Every character on the display stands out and the wide viewing angle allows measurements to be seen from any angle. The backlight is adjustable for perfect viewing and a backlight saver option protects the display during periods of inactivity.

Detailed titration graphs
A real-time titration curve can be displayed during each titration; this feature is useful when new methods are tested or when a procedure requires optimization.

 

Connectivity and functionality

Rear connections
HI930 offers support for one analog board to allow a pH or ORP electrode and one burette to be connected.

Multifunctional versatility
HI930 functions as a titrator, pH meter, and mV/ORP meter. Valuable laboratory bench space is saved, and multiple analyses can be performed on one sample.

 

Data

Data storage
Up to 50 titration and pH/mV reports can be stored. Transfer data via USB.

Effortless data transfer
A conveniently located USB port allows for the transfer of titration methods, titration reports, and software upgrades.

Flexible GLP management
All necessary Good Laboratory Practice (GLP) information is recorded with each sample including sample identification, company and operator name, date, time, electrode ID codes, and calibration information.

Enhanced security options
Administrative users can set a PIN code on the device protecting against unauthorized access. Titration method options and results are tamper-proof while a non-administrator operates the titrator, ensuring records remain safe, secure, and traceable.

 

Electrode holder

The holder is angled for access to smaller volume titrations without hassle. Use electrodes with different diameters by simply changing the electrode guide. No need to move electrodes around, get the best tube alignment for your titration with a rotating holder. For a more compact design, the electrode holder is mounted directly onto the titrator body. The press-torelease button makes for simple height control.

Specifications

Specifications

HI930

Analysis Type

 

Standard titration (Standardization, Fixed pH / mV, Equivalence point pH / mV)

End Point Mode

 

Fixed mV Fixed pH

mV Equivalence Point (1st or 2nd derivative) pH Equivalence Point (1st or 2nd derivative)

Burette

Size

5 mL, 10 mL, 25 mL, 50 mL

 

Resolution

0.001 mL

 

Flow Rate

0.1/0.3 mL to 2 × burette volume per minute

 

Accuracy

±0.005 mL (5 mL Burette)

±0.010 mL (10 mL Burette)

±0.025 mL (25 mL Burette)

±0.050 mL (50 mL Burette)

Stirrer

Type

Integrated magnetic

 

Range

200 to 1400 RPM

 

Resolution

100 RPM

mV

Range

-2000.0 to 2000.0 mV

 

Resolution

0.1 mV

 

Accuracy

±0.1 mV

 

mV Calibration

Single point offset

pH

Range

−2.000 to 20.000 pH

 

Resolution

0.1 / 0.01 / 0.001 pH

 

Accuracy

±0.001 pH

 

pH Calibration

Up to 5 points with standard or custom buffers

Temperature

Range

−5.0 to 105 °C

23.0 to 221.0 °F

268.2 to 378.2 K

 

Resolution

0.1

 

Accuracy

±0.1 °C / ±0.2 °F / ±0.1 K

Data Storage

Methods

Up to 15 titration methods (standard and user-defined)

 

Reports

Up to 50 titrations and pH / mV reports

Connections

Measurement

1 × BNC socket (pH, ORP electrodes)

1 × 4 mm banana socket (reference electrode) 1 × RCA socket (temperature sensor)

 

Peripherals

1× USB standard A (USB flash drive)

Additional Specifications

Electrode Holder

4× multi-purpose slots (titrant tubes)

4 × 12-mm electrode slots (3 integrated, 1 with included adapter)

1 × temperature sensor slot

 

Display

5.7″ graphical color display with backlight

 

Power Supply

100 – 240 VAC, 50 / 60 Hz

 

Enclosure material

ABS, PC-ABS, stainless steel

 

Keypad

Polyester

 

Power Draw

0.5 Amps

 

Operating Environment

10 to 40 °C (50 to 104 °F); up to 95 % RH

 

Storage Environment

−20 to 70 °C (−4 to 158 °F); up to 95 % RH

 

Dimensions

315 × 205 × 375 mm (12.4 × 8.1 × 14.8 “)

 

Weight

Approximately 3.6 kg (7.9 lbs.) with burette

Manuals

Ordering info

Each HI930 potentiometric titrator is supplied with:
• Titrator
• Pump assembly
• Burette assembly
• Burette with 25 mL syringe
• Aspiration tube with fitting and protection tube
• Dispensing tube with dispensing tip, protection tube, and tube guide
• Tube locks
• Tool for burette cap removal
• Light spectrum protection screen
• Plastic beaker, 100 mL (3 pieces)
• Beaker support
• Electrodes holder and support rod with positioning collar and screw
• Magnetic stirrer
• Stir bar (2 pieces)
• Pump and burette locking screws with plastic head
• Temperature sensor
• Shorting cap
• O-ring set (5×10.5 mm + 5×3 mm)
• Power adapter
• USB memory stick
• Instrument quality certificate
• Instruction manual

Where to buy

Mediray is Hanna Instruments’ authorised distributor in New Zealand. To purchase our products, please see the details below.

Phone: 0800 633 472

[email protected]