The HI930 Automatic Potentiometric Titration System is the answer to your basic titration needs. The HI930 delivers accurate results and intuitive user experience, all in a compact package. Titrate for a variety of measurements at the push of a button including acids, bases, and redox. With no additional programming upgrades to purchase, you can start measuring right away.
Maximize your workspace
This new generation of titrator features a compact footprint for maximum use of your lab space. Use it in any sized space while providing accurate and consistent results.
Simple user experience
Virtual keys present on the display allow for simple and quick navigation between screens and menus without getting lost in a nest of information. If you need additional information about a screen, simply press the dedicated button for help.
Designed for dynamic environments
Don’t worry about small spills in the laboratory with built-in spill handling. An external gutter system protects important connections and interior trays safeguard internal electronics.
Superior design for superior results
The Cycoloy® body is durable, heat-resistant, and resists staining. Menu buttons are part of the display making it fully sealed and easy to clean.
Titrator capabilities
Multiple titration types
Paired with the right electrode, this potentiometric titrator can perform any number of standard titrations including pH and mV tests with fixed endpoints or single equivalence points.
Dynamic titrant dosing
The dynamic dosing feature allows for timely and accurate titration results by relating the titrant volume dosed to the mV response from the titration reaction. This provides for larger doses near the beginning of a titration and smaller, more precise doses near the titration endpoint.
Equivalence endpoint detection
Equivalence endpoint detection is critical in applications where fixed endpoints are not specified in standard methods. This endpoint indicates where the mV response from the titration is greatest with respect to the volume of titrant dosed.
Signal stability timing
The signal stability feature monitors when the mV response of the titration reaction stabilizes before providing the next titrant dose. This ensures reliable measurement values throughout the length of a titration.
Customizable methods
This titrator can store up to 15 user-defined or standard titration and direct measurement methods. Each method may be modified and optimized for performance based on application and user requirements.
Customizable analysis reports
Each analysis report is fully customizable to ensure the best data required for an application is stored and filed. The Multiselect feature makes batch processing simple.
Burettes and dosing system
Clip Lock™ exchangeable burette system
With Hanna’s Clip-Lock™ burette feature, it only takes a few seconds to exchange titrants and reagents preventing cross-contamination and saving time.
Multiple burette sizes
HI930 is supplied with a 10 mL burette but may be equipped with a 5 mL, 25 mL, or 50 mL burette. Each burette is constructed with a ground glass syringe and chemically resistant PTFE plunger.
Precision dosing pump
Our unmatched 40,000-step piston driven pump is capable of dosing extremely small and highly accurate volumes of titrant or reagent.
Chemically resistant tubing
Aspiration and dispensing tubes are constructed of durable, chemically resistant PTFE and feature a light-blocking polyurethane outer sleeve to protect light sensitive reagents.
Interface and display
Interactive color display
A large, high contrast LCD display clearly shows the chosen titration method along with results, units, titration volume, temperature, and mV or pH values. Every character on the display stands out and the wide viewing angle allows measurements to be seen from any angle. The backlight is adjustable for perfect viewing and a backlight saver option protects the display during periods of inactivity.
Detailed titration graphs
A real-time titration curve can be displayed during each titration; this feature is useful when new methods are tested or when a procedure requires optimization.
Connectivity and functionality
Rear connections
HI930 offers support for one analog board to allow a pH or ORP electrode and one burette to be connected.
Multifunctional versatility
HI930 functions as a titrator, pH meter, and mV/ORP meter. Valuable laboratory bench space is saved, and multiple analyses can be performed on one sample.
Data
Data storage
Up to 50 titration and pH/mV reports can be stored. Transfer data via USB.
Effortless data transfer
A conveniently located USB port allows for the transfer of titration methods, titration reports, and software upgrades.
Flexible GLP management
All necessary Good Laboratory Practice (GLP) information is recorded with each sample including sample identification, company and operator name, date, time, electrode ID codes, and calibration information.
Enhanced security options
Administrative users can set a PIN code on the device protecting against unauthorized access. Titration method options and results are tamper-proof while a non-administrator operates the titrator, ensuring records remain safe, secure, and traceable.
Electrode holder
The holder is angled for access to smaller volume titrations without hassle. Use electrodes with different diameters by simply changing the electrode guide. No need to move electrodes around, get the best tube alignment for your titration with a rotating holder. For a more compact design, the electrode holder is mounted directly onto the titrator body. The press-torelease button makes for simple height control.